Intermittent Operation
Intermittent operation -
More punctual than German Rail, no matter how often you stop.
Speed: in average 2.5 m/min
Task: to stop 800 times per minute and carry out a measurement
Equipment: H-cartesian robot (Bahr Modultechnik), two 34S42-0560-A03JA-AA,
one 23S21-0560-803JA-AA (z-axis) and three ECOSTEP®200-AA

|
Quality
test for keyboards
|
 |
 |
|
To be in time the z-axis testing motor (function
check by current observation) has to be moved 800 times per minute
quite accurate.
|

|